ts-3

TS 2V, Electric locomotive, Traction start, Lighting

Range Summary

TS series, under name of Traction Series, is VRLA battery special designed for diesel locomotive and electric locomotive starting, lighting and signal system.

With reliable heat sealing, patented pole sealing technology and special deep cycle alloy formulation, TS series has excellent deep discharge recovery, large current discharge performance.

Technical Features

• AGM-Acid Valve-Regulated Lead Acid battery
• Patent design for higher reliability & performance
• Patent Terminal sealing
• Self-regulating pressure relief valve with flame arrester
• Excellent discharge performance.
• Flame retardant ABS case (UL94 V-0, optional)
• For locomotive with diesel engine running 4-6 years.
• For locomotive with electric engine running 8 years.
• Self-discharge<0.077%/day @ 25°C (77°F)
• Start life>10000 times.
• Comply with IEC, IEEE, UL, EN, CE standards, etc.

Main Applications

• Electric locomotive starting
• Lighting, signaling systems
• Other standby power systems

General Specifications

Type Nominal Voltage Rated
Capacity(Ah)
Dimensions(mm) Weight
(Kg)
PDF
C5 C10 Length Width Height Total Height

DLM-170

2V

170Ah

172

85

352

363

12.4

NM-450

2V

450Ah

223

187

360

370

36.5

DTM-160

2V

160Ah

114

143

311

320

13.0

DTM-180

2V

180Ah

128

143

311

320

14.5

eos-4

Eos 2V, AGM, Standard

Range Summary

Eos series, under the name of “God Eos”, is a most typical 2V large capacity VRLA battery in Narada, it has four generations and widely implemented in field where large batteries needed. With patent terminal sealing, Lid sealing & Safety valve, Eos series is installed horizontal, and bring a lot of benefits, e.g., less footprint, easy installation & maintenance, long life. Eos series is mainly designed as standby power for Telecom, Datacenter, Utilities, and Uninterruptible power supplier.

Technical Features

• AGM-Acid Valve-Regulated Lead Acid battery
• Patent precise Terminal glue sealing & ABS Heat sealing
• Horizontal installation position for less space, easy installation & maintenance
• Soft & hard connector with complete insulation and maintenance access hole
• Self-regulating pressure relief valve with flame arrester
• Flame retardant ABS case (UL94 V-0, optional)
• Low self-discharge rate
• High gas recombination efficiency (>99%)
• Customized rack design for up to 9-class or Zone 4 application
• Comply with IEC, IEEE, UL, EN, CE standards, etc.
• Design life at 25°C (77°F): 15+ years

Main Applications

• Telecommunication
• UPS
• Power plant and power transformer system
• Navigation aid signaling system
• Solar energy system
• Radio and broadcasting station
• Emergency lighting system
• Other standby and cyclic systems

General Specifications

Type Nominal Voltage Rated
Capacity(Ah)
Dimensions(mm) Weight
(Kg)
Pdf
C10(1.80Vpc @25℃) Length Width Height Total Height

Eos-200

2V

200

94.5

184.5

360.5

372

13.5

EOS200

Eos-300

2V

300

123

184.5

360.5

372

18.5

EOS300

Eos-400

2V

400

166

184.5

360.5

372

24.5

EOS400

Eos-500

2V

500

194.5

184.5

360.5

372

29.5

EOS500

Eos-600

2V

600

223

184.5

360.5

372

35.0

EOS600

Eos-800A

2V

800

280

186

360.5

372

47.0

EOS800A

Eos-800

2V

800

154

229

555

566

52.0

EOS800

Eos-1000A

2V

1000

339

190

360.5

372

58.0

EOS1000A

Eos-1000

2V

1000

186

229

555

566

62.0

EOS1000

Eos-1200

2V

1200

225

229

555

566

75.0

EOS1200

Eos-1500

2V

1500

265.5

229

555

566

92.0

EOS1500

Eos-2000

2V

2000

349

233

555

566

121.0

EOS2000

Eos-3000A

2V

3000

496

363

361.7

373.5

175.0

EOS3000A

mpg-1

MP 12V, Standard, Front terminal

Range Summary

MP series, under the name of “Marathon Purpose”, is a front terminal VRLA battery too, but with more conservative design to ensure high reliability and long life. Front terminal and centralized venting system design makes MP series become popular product for standard 19”/21” cabinet since easier installation & maintenance. MP series is mainly designed for Telecom, UPS as a premium front terminal battery.

Technical Features

• AGM-Acid Valve-Regulated Lead Acid battery
• Premium design for higher reliability & performance
• Front terminal design suited for 19”/21” cabinet
• Strong handles for easy operation
• Patent Terminal sealing & front access
• Self-regulating pressure relief valve with flame arrester
• Terminal cover for insulation with flexible access
• Flame retardant ABS case (UL94 V-0, optional)
• Centralized H2 gas vent kit
• Comply with IEC, IEEE, UL, EN, CE standards, etc.
• Design life at 25°C (77°F): 12+ years

Main Applications

• Telecommunications
• Uninterruptible power supply (UPS)
• Switchgear / utility
• Other applications to provide integrated stored energy systems

General Specifications

Type Nominal Voltage Rated
Capacity(Ah)
Dimensions(mm) Weight
(Kg)
PDF
C10 (1.80Vpc@25℃) Length Width Height Total Height

6-GFM-50F

12V

50

390

105

227

227

20.7

 

6GFM50F

6-GFM-85F

12V

85

395

105

270

270

28.0

 6GFM85F

6-GFM-100F

12V

100

558

125

227

227

37.5

 6GFM100F

6-GFM-100FB

12V

100

395

108

287

287

32.0

 6GFM100FB

6-GFM-105F

12V

100

511

110

238

238

34.0

 6GFM105F

6-GFM-125F

12V

125

558

125

270

270

47.8

 6GFM125F

6-GFM-125FB

12V

125

550

110

285

285

40.0

 6GFM125FB

6-GFM-150FB

12V

150

550

110

285

285

44.0

 6GFM150FB

6-GFM-150F

12V

150

558

125

310

310

51.0

 6GFM150F

6-GFM-155F

12V

155

559

125

283

283

53.0

 6GFM155F

6-GFM-155FC

12V

155

550

110

285

285

48.0

 6GFM155FC

6-GFM-170F

12V

170

558

125

310

310

55.0

 6GFM170F

6-GFM-200M

12V

200

498

259

238

238

67.0

 6GFM200M
acme-1

Acme 12V, Standard, Front terminal

Range summary

Acme series, under the name of “the Best”, is a first front terminal VRLA battery in China. Front terminal and centralized venting system design makes Acme series become popular product for standard 19”/21” cabinet since easier installation & maintenance.     As a stationary battery, Acme series provides higher specific energy and long standby life.

Technical Features

• AGM-Acid Valve-Regulated Lead Acid battery
• Front terminal design suited for 19”/21” cabinet•
• Strong handles for easy operation
• Patent Terminal sealing & front access
• Self-regulating pressure relief valve with flame arrester
• Terminal cover for insulation with flexible access
• Flame retardant ABS case (UL94 V-0, optional)
• Centralized H2 gas vent kit
• Low self-discharge rate
• Comply with IEC, IEEE, UL, EN, CE standards, etc.
• Design life at 25°C (77°F): 12+ years

Main Applications

• Telecommunication
• UPS
• Other standby system

General Specifications

Type Nominal Voltage Rated
Capacity(Ah)
Dimensions(mm) Weight
(Kg)
PDF
C10 (1.80Vpc@25℃) Length Width Height Total Height

12NDT26

12V

26

250

97

146.5

148.5

9.3

 12NDT26

 

12NDF50

12V

50

390

105

200

200

21.0

 

12NDF50

12NDF85

12V

85

390

105

270

270

31.0

 12NDF85

12NDF100

12V

100

390

105

287

287

33.0

 

12NDF100

12NDT100A

12V

100

390

105

287

287

32.5

 12NDT100A

12NDF125

12V

125

558

125

270

270

45.0

 

12NDF125

12NDF155

12V

155

558

125

270

270

52.5

 

12NDF155

12NDT180

12V

180

558

125

316

316

60.0

 12NDT180

12NDT190

12V

190

558

125

316

316

60.5

 

12NDT190

12NDT200 12V 200 558 125 316 316 61.0  12NDT200
12NDT100S 12V 100 395 108 287 287 31.0

 

12NDT100S

12NDT150S 12V 150 550 125 283 283 48.0  

12NDT150s

12NDT170S 12V 170 550 125 283 283 51.5  12NDT170S
12NDT190S 12V 190 558 125 316 316 59.0  12NDT190S
12NDT200S 12V 200 558 125 316 316 59.5  

12NDT200S

Acme series operation manual V4.2